Strong and solid
Hebel Systems
Fire Walls
Hebel’s PowerShield High Performance Fire Wall Systems are certified for hydrocarbon fire exposure, protecting power utility and infrastructure assets, such as road tunnels, against petrochemical fire. Suitable for critical asset wall enclosures and ceilings in tunnels and to protect support structures of the wall and ceiling systems.
Designed to withstand heat up to 1300°C, the PowerShield systems achieve high fire resistance performance when exposed to the Hydrocarbon Modified (HCM) curve for 2 hours (Exova Warringtonfire Fire Assessment 28255-04 RIR). When exposed to cellulosic fire, the systems achieve an FRL of-/240/240 (for horizontally installed wall panels up to 6000mm high) in accordance with AS 1530.4-2005 (Exova Warringtonfire Fire Assessment 24648-07).
Tested and proven for thermal and acoustic performance as well as fire resistance, the systems can be used for new structures or retrofitted. Column protection is achieved by encasing the steel member with the Hebel PowerShield panel. For walls in electromagnetic fields, non-inductive panels can be supplied. Panel thickness ranges from 150mm to 300mm in lengths up to 6 meters.
The PowerShield systems are easy to install where there is restricted site access and does not require heavy lifting equipment, a distinct advantage compared with concrete.
System Application | System code | Acoustic STC | Acoustic Rw | Fire performance / Hydrocarbon | Fire performance / Cellulosic (FRL) | Panel thickness | Wall height | Wall length | Panel installation | ||
---|---|---|---|---|---|---|---|---|---|---|---|
label PowerShield High Performance Fire Wall System for up to 7 metres high, steel support columns not required | System code HEB 3001 | For tunnel linings, substation enclosures | Acoustic STC 43-51 | Acoustic Rw Rw = 43 - 51dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/120/120 | Panel thickness 150 - 300mm | Wall height H≤6000mm | Wall length Unlimited | Panel installation Vertical | |
label PowerShield High Performance Fire Wall System for up to 7 metres high, steel support columns not required | System code HEB 3002 | For tunnel linings, substation enclosures | Acoustic STC 43-51 | Acoustic Rw Rw = 43 - 51dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/120/120 | Panel thickness 150 - 300mm | Wall height H≤7000m (stitch / splice plate in upper 2000mm) | Wall length Unlimited | Panel installation Vertical | |
label PowerShield High Performance Fire Wall System for up to 10 metres high, simple connection | System code HEB 3003 | For tunnel linings, substation enclosures | Acoustic STC 43-51 | Acoustic Rw Rw = 43 - 51dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/240/240 | Panel thickness 150 - 300mm | Wall height H≤6000mm | Wall length L≤6000mm | Panel installation Horizontal | |
label PowerShield High Performance Fire Wall System for up to 10 metres high, simple connection | System code HEB 3004 | For tunnel linings, substation enclosures | Acoustic STC 43-51 | Acoustic Rw Rw = 43 - 51dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/120/120 | Panel thickness 150 - 300mm | Wall height H≤10000mm | Wall length L≤6000mm | Panel installation Horizontal | |
label PowerShield High Performance Fire Wall System for narrow width with services | System code HEB 3005 | For tunnel linings | Acoustic STC 38 | Acoustic Rw Rw = 38dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/120/120 | Panel thickness 100mm | Wall height Unlimited subject to steel support framing system design | Wall length Unlimited subject to steel support framing system design | Panel installation Vertical or horizontal. Panel fixed to steel support framing system at max.450mm centres | |
label PowerShield High Performance Fire Ceiling System with services above | System code HEB 3006 | For tunnel linings | Acoustic STC 38 | Acoustic Rw Rw = 38dB | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) -/120/120 | Panel thickness 100mm | Wall height N/A | Wall length Unlimited subject to steel support framing system design | Panel installation Perpendicular to framing. Panel fixed to steel support framing system at max.450mm centres | |
label PowerShield High Performance Steel Column Fire Protection System with monolithic face finish | System code HEB 3007 | For substation enclosures | Acoustic STC N/A | Acoustic Rw N/A | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) 120/-/- | Panel thickness 150mm | Wall height H≤10000mm subject to steel column design | Wall length N/A | Panel installation Vertical | |
label PowerShield High Performance Steel Column Fire Protection System for existing structural column elements with narrow access | System code HEB 3008 | For substation enclosures | Acoustic STC N/A | Acoustic Rw N/A | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) 120/-/- | Panel thickness 150mm | Wall height H≤10000mm subject to steel column design | Wall length N/A | Panel installation Vertical | |
label PowerShield High Performance Steel Column Fire Protection System for existing structural column elements at wall junctions with narrow access | System code HEB 3009 | For substation enclosures | Acoustic STC N/A | Acoustic Rw N/A | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) 120/-/- | Panel thickness 150mm | Wall height H≤10000mm subject to steel column design | Wall length N/A | Panel installation Vertical | |
label PowerShield High Performance Steel Column Fire Protection System for corner structural elements with narrow access | System code HEB 3010 | For substation enclosures | Acoustic STC N/A | Acoustic Rw N/A | Fire performance / Hydrocarbon 120 minutes | Fire performance / Cellulosic (FRL) 120/-/- | Panel thickness 150mm | Wall height H≤10000mm subject to steel column design | Wall length N/A | Panel installation Vertical |